Tripp Lite SUDC208V42P60M Datasheet

Browse online or download Datasheet for Racks Tripp Lite SUDC208V42P60M. Tripp Lite SUDC208V42P60M racks User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 3
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
Model #: SUDC208V42P60M
60kVA 3 Phase Power Distribution Center with Integrated 3 breaker 208V Service Bypass Switch
Highlights
Full size 42U Rack Power Distribution Center supports 60kVA 3 phase UPS
power distribution in datacenter equipment racks
Integrated 3 breaker 208V service bypass switch enables hot-swap
replacement of 60kVA 3 phase UPS systems without dropping the connected
critical loads
42 pole breaker panel supports 3 phase, 208V and single phase 208V and
120V outputs to connected equipment
Pre-installed 225A, 3 pole main breaker, ground and neutral bars
Secure front and rear doors, removable side panels
Full line of accessories includes circuit breakers, corded receptacle whips and
PDUs
Description
Tripp Lite's SUDC208V42P60M Power Distribution Center supports 60kVA 3 phase UPS power distribution in critical datacenter equipment racks.
Integrated 3 breaker 208v service bypass switch enables hot-swappable replacement of 60kVA 3 phase UPS systems without dropping the
connected critical loads. Full size 42U rack enclosure with pre-installed 42 pole circuit breaker panel supports 3 phase 208V and single phase 208V
and 120V output via optional corded receptacle whips. Breaker panel includes 225A, 3 pole main breaker, ground and neutral bars, plus 1/2, 3/4
and 1 inch knockouts. Rack enclosure offers secure front and rear doors, removable side panels and shares common dimensions and overhead
wiring tray accessories as Tripp Lite SR42UB rack enclosures. Compatible with Tripp Lite SUBB-series 1, 2 and 3 pole breakers, SUWL-series
corded receptacle whips and a full line of compatible basic, metered, monitored and switched PDUs to support a variety of advanced network
configurations.
Features
SUDC208V42P60M Power Distribution Center supports 60kVA 3 Phase UPS power distribution in critical datacenter equipment racks
Integrated 3 breaker 208v service bypass switch enables hot-swappable replacement of 60kVA 3 phase UPS systems without dropping the
connected critical loads
Full size 42U rack enclosure with pre-installed 42 pole circuit panel supports 3 phase 208V and single phase 208V and 120V outputs via
optional corded receptacle whips, snap-in panel breakers and PDUs
Line up and match power distribution cabinet blends with existing standard datacenter racks for an aesthetically pleasing appearance while
providing convenient connectivity between the centralized 3 phase UPS and protected electronic devices in equipment racks
Breaker panel includes 225A 3 pole main breaker, ground and neutral bars, 1/2, 3/4 and 1 inch knockouts (see Help & Downloads for
manual with detailed wiring information)
Rack enclosure offers secure front and rear doors, removable side panels and shares common dimensions and overhead wiring tray and
ladder accessories as Tripp Lite SR42UB equipment racks
Requires appropriate SUBB-series output circuit breakers (see Related Items for list of compatible SUBB breakers)
Optional SUWL-series cable whips and SUWEL-series extensions support a variety of connector types, voltages and cable lengths (see
Related Items for list of compatible SUWL-series and SUWEL-series cabling accessories)
Optional full line of Basic, Metered, Monitored and Switched PDUs available
Page view 0
1 2 3

Summary of Contents

Page 1 - Model #: SUDC208V42P60M

Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SUDC208V42P60M60kVA 3 Phase Pow

Page 2 - Related Items

SpecificationsOVERVIEWModel Type CabinetsPHYSICALShipping Dimensions(HWD/in)84.5 x 27.75 x 47Shipping Dimensions(HWD/cm)214 x 70.5 x 119Unit Dimension

Page 3

Single-Phase Whips SUWL520C-40 120V Single Phase Whip in 40 ft. length with L5-20R output forBreakered 3 Phase Distribution Cabinet Applications 1Sing

Comments to this Manuals

No comments