Tripp Lite SU60K Datasheet Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
SU60K UPS System
PowerAlert Software and cabling
Parallel cable (for 1+1 operation)
Instruction manual and startup checklist
Warranty information
Features
N+1 configuration: three self-contained, redundant 20kVA power modules can be hot-swapped (with the load powered) if maintenance is
required
1+1 configuration: connect two SU60K models in parallel to provide fail-safe redundancy or to increase capacity
High input power factor, advanced IGBT inverter technology and Digital Signal Processor (DSP) technology create low input Total Harmonic
Distortion (THDi)
Extremely efficient operation (up to 96%) saves money by lowering electricity consumption
True on-line, double conversion UPS with IGBT technology provides pure, sine wave AC output at all times
Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
60,000VA/48,000W power capacity with 3-phase, hardwire 120/208VAC input/output connections
Features a wide input voltage correction range: 94-150/163-260VAC
A stand-alone hardwired external battery module (Models BP480V26B and BP480V40C, available separately from Tripp Lite) is required for
operation and to provide battery backup support. Additional external battery modules can be connected for extended runtime.
Front panel combination LCD/LED display includes a real-time event log screen with up to 500 events listed
Dynamic battery management screen optimizes battery function to lengthen service life and allows cold restart of UPS
Built-in RS-232 communication port works with included PowerAlert Software to provide shutdown commands and reporting on a single
server
Accessory slot accepts an optional internal SNMP card (Model SNMPWEBCARD) for remote shutdowns, reboots and more
Emergency Power Off button turns UPS output OFF and disables Bypass output
Built-in Emergency Power Off (EPO) dry-contact interface supports remote emergency shutdown in large facilities
1-year limited repair warranty
Start-up service program is recommended to enhance the reliability of the installation
Specifications
OUTPUT
Output Volt Amp
Capacity (VA)
60000
Output kVA capacity
(kVA)
60
Output Watt
Capacity (watts)
48000
Output kW capacity 48
Output power factor 0.8
Crest Factor 3:1
Nominal Output
Voltage(s) Supported
120/208V; 3-Phase Wye
Frequency
compatibility
50 / 60 Hz
Output voltage
regulation (line
mode)
+/- 2%
Output voltage
regulation (Battery
mode)
+/- 2%
Page view 1
1 2 3 4 5 6

Comments to this Manuals

No comments