Tripp Lite PowerVerter Owner's Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
7
Configuration
(continued)
SetBatteryChargeConserver(LoadSense)Control—OPTIONAL
In order to save battery power, the unit's inverter automatically shuts off in the absence of any power demand from
connected equipment or appliances (the electrical load). When the Inverter/Charger detects a load, it automatically turns its

Conserver Control (see diagram). Using a small tool, turn the control clockwise to lower the minimum load that will be
detected, causing the inverter to turn on for smaller loads. When the control is turned fully clockwise, the inverter will
operate even when there is no load. Turn the control counterclockwise to increase the minimum load that will be
detected, causing the inverter to stay off until the new minimum load is reached.
NOTE: The factory setting for the control is fully clockwise. However, based on the threshold load to which you’d like the inverter to respond, you should adjust the control counterclockwise to reduce
its sensitivity until the inverter is active only when connected equipment or appliances are actually in use.
ConnectRemoteControl—OPTIONAL

separately). The remote module allows the Inverter/Charger to be mounted in a compartment or cabinet out of sight, while operated
conveniently from a remote location. See instructions packed with the remote control module.
LOAD
SENSE
MAX OFF
LOAD
SENSE
MAX OFF
Connect Battery Temperature Sensing Cable—OPTIONAL (Contact Tripp Lite for optional temperature sensing cable
accessory.)





or cold. If the sensor cable is not used, the Inverter/Charger will charge according to its default value

ConnectAutomaticGeneratorStarter—OPTIONAL
             

            
generator on when connected battery voltage levels are low and switch it off when
battery voltage levels are high.
Pin Configuration
2 - Common
3 - N.C.
(Normally Closed)
4 - N.O.
(Normally Open)
1
2
3
4
5
6
Select Battery Type - REQUIRED
Battery Type Switch Position
AGM/Gel Cell (Sealed) Battery Up
Wet Cell (Vented) Battery Down (factory setting)
12
CAUTION: The Battery Type DIP Switch setting must match the type of
batteries you connect, or your batteries may be degraded or damaged
over an extended period of time. See “Battery Selection,” for more
information.
9 10 11 12
AGM/
Gel Cell
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 47 48

Comments to this Manuals

No comments