Communications port enables safe unattended shutdown without data loss during extended power failures
Communications port supports messaging of UPS and line power status, including on-battery, low-battery, power-restored, AC line voltage,
DC battery voltage and battery capacity
Communications port supports timed inverter shutoff after unattended shutdown, activate self-test and 10-second reboot of connected
equipment
PowerAlert UPS monitoring and unattended shutdown software with complete cabling included
Battery replacement door allows on-site hot-swap battery replacement
Supports Tripp Lite's WatchDog software application to restore unresponsive programs by automatically restarting them and rebooting
completely locked computers by automatically switching UPS power off and back on again
Notification of system status via 5 LEDs and multi-function audible alarms
Wall mountable with UPSWM wallmount bracket
Cold start capability enables UPS turn-on in battery mode during blackout conditions
$250,000 Ultimate Lifetime Insurance
2-year manufacturer product warranty
Specifications
SYSTEM OVERVIEW
Voltage
compatibility
120V AC
Frequency
compatibility
60Hz
OUTPUT
Output VA 750
Output watts 450
Output nominal
voltage
120V AC
Output voltage
regulation
LINE MODE: Sine wave line voltage 120V (-18% / +8%)
Output frequency
regulation
LINE MODE: Passes line frequency of 60Hz +/-10%
Outlet quantity /
type
6 NEMA 5-15R
INPUT
Maximum input
amps
4.4A / 490 watts
Input connection
type
NEMA 5-15P
Input cord length 6 ft., 16 gauge
Recommended
Electrical Service
15A 120V
BATTERY
Full load runtime 5.5 minutes (750VA)
Half load runtime 16 minutes (375VA)
DC system voltage 12V DC
Typical battery
lifespan
3-6 years, depending on usage
Battery recharge
rate
Less than or equal to 6 hours to 90%
Replacement
Battery Cartridge
RBC52 (quantity 2)
VOLTAGE REGULATION
Voltage regulation
description
Automatic Voltage Regulation (AVR) circuits maintain clean, regulated computer-grade 120V nominal output, without using
battery power, during brownouts to 75V and overvoltages to 147V