Tripp Lite 500FC User Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
7
5. BATTERY HIGH/MED/LOW (All models)
These three lights will turn ON in several sequences to show the approximate charge level and
voltage of your connected battery bank and alert you to several fault conditions:
LEDs Illuminated Capacity
Green Full
Green & yellow 80% - Full
Yellow 60% - 80%
Yellow & red 40% - 60%
Red 20% - 40%
Flashing red, twice/second 0% - 20%
Flashing red, 4 times/second 0% (Inverter shutdown)
Other Features
6. DC Input Terminals (All models)
The terminals' lug screws or wing nuts secure the wires leading from your external battery or battery
system. Your battery or battery system must provide your PowerVerter with proper DC voltage and
your equipment with an adequate amp hour capacity. See Battery Selection section, pg. 4 for more
information.
7. Resettable Circuit Breaker (All models)
The circuit breaker protects your PowerVerter against damage due to output overload. If the breaker
trips, remove some of the load on the PowerVerter to prevent overload, then wait 1 minute to allow
components to cool before resetting the circuit breaker.
8. Remote On/Off Switch Connector (PV 500FC and PV 1000FC)
This jack can be used to connect a user-supplied corded on/off switch for remote control.
9. APS/PV Remote Connector (PV 2000FC and PV 2400FC)
This RJ11 jack can be used to connect an optional Tripp Lite APS/PV Remote (sold seperately) to
monitor and control the operation of the PowerVerter at a distance. See the instructions packed with
the APS/PV Remote for installation, operation and maintenance.
200002001 CURRENT PV 500-2400FC.p65 6/22/00, 11:39 AM7
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 19 20

Comments to this Manuals

No comments