Page view 0
9
TRIPPaUTE
POWER PRorEcTloN
N
11 11
W.
35th Street
Chlcago,
IL
60609 USA
Customer Support:
(773) 869-1234
Application Services: (773) 869-1236
www.tripplite.com
1
Capyrighl
0
MOI
Tripp
tile.
All
ri@u
mrved.
Smam3nlieN
is
a
rcgisterrd
trademark
of
Tripp
Lite.
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - TRIPPaUTE

9 TRIPPaUTE POWER PRorEcTloN N 11 11 W. 35th Street Chlcago, IL 60609 USA Customer Support: (773) 869-1234 Application Services: (773) 869-1236 www.tr

Page 2 - Battery Warnings

SELF-TESTING When you turn the UPS ON, it will perform a brief (about 25 second) self-test. See figure below for display sequence.' 'Note:

Page 3

LCD DISPLAY SELECT SWITCH Momentarily press the "SELECT" switch on the front panel to browse through different power readings on the LCD Di

Page 4

BATERY CHARGE WA RNlNGS Since your UPS can provide battery backup only for as long as the batteries remain charged, these warnings should be acted on

Page 5 - REAR PANELS

RS-232 INTERFACE This female DB9 port connects your UPS via an RS-232 cable to a workstation or server equipped with Tripp Lite software. The port use

Page 6 - (SUIOKPM

DRY CONTACT INTERFACE: This female DB9 contact-closure port allows your UPS to send contact-closure signals to indicate that it is on battery back-up

Page 7 - INPUTAND OUTPUT CONNECTION

Service Your Smartonline UPS is covered by the 2-year limited warranty period described below. A variety of service contracts is also available f

Page 8 - REPLACEMENT

*' SURGE PROTECTOR ACINPUT SUBP EXTERNAL BATTERY CABINET(S): STATIC BYPASS SW~CH INPUT FILTER STANDARD BAllERIES: 240 VDC dLs DCTOAC INVERTER * I

Page 9 - TURNING THE UPS

(Notc: Excludingisolation transformer) Model SU6K SUlOK && Inputvoltage 156V-280VSlngle Phase 156V-280VSinglePhase Input Frequency 50/60 H

Page 10 - Sltll~lOlllll~

This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite Sm

Page 11 - OPERATION ON OVERLOAD

Familiarize yourself with the location and function of the front and rear panel features before installing and operating your UPS. FRONT PANEL 0 0 0

Page 13 - AS-400 INTERFACE:

REAR PANELS 1. Manual Bypass Switch: This red and yellow dial is used in one step of putting the UPS in "BYPASS" mode, which must be done b

Page 14 - .'

INVERTER OPERATION DIP SWITCH SETTINGS (SUIOKPM SHOWN) Using a small tool, set the four Inverter Opera- tion DIP Switches (located on the rear panel o

Page 15 - Service

UPS LOCATION Move your UPS over short distances using its wheels. Stabilize the UPS by releasing the stabilizers on each side of the unit. NOTE: Do

Page 16

EXTERNAL BATTERY PACK CONNECTION (SUGK: Optional; SU1OK: Required) Since SUGK models contain internal batteries, connecting external battery packs (t

Page 17 - &&

BA77ERY CONDITION VERIFICATION When the UPS is operating from battery power, the alarm and LCD Display will both alert you to the UPS battery's