General Operation Troubleshooting
Administration Troubleshooting
Problem Action
Erratic Operation If a KVM switch is cascaded from it, the upper-level KVM must always be powered on before the lower-
level KVM. If the cascaded switch was turned on first, resetting it may resolve the issue. If not, power off
the installation and power everything on according to the installation instructions in this manual.
• Reset the unit by pressing and holding the Reset button on the front of the unit for longer than three
seconds.
I can’t access the B064-Series KVM
Switch, even though I have specified the
IP address and port number correctly.
If the B064-Series KVM Switch is behind a router, the router’s Port Forwarding (also referred to as
Virtual Server) feature must be configured.
Mouse and/or Keyboard not responding. • If accessing the KVM via local console, unplug and replug the cable(s) from the console port(s).
Turn the connected computer/server off and then back on. All connected devices need to be powered
off when connecting to the KVM.
Sudden loss of network connection. Close your B064-Series KVM Switch connection. Wait approximately 30 seconds, and log in again.
No video display on the remote console. • Make sure the resolution of the monitor being used to display the remote computer/server is higher
than that of the remote computer/server.
• Make sure the OSD toolbar is closed. Sometimes mouse movement is required to bring the screen out
of sleep mode. If the OSD toolbar is open, your mouse input is not being received by the remote
computer/server.
Check the rmware version number of the Server Interface Unit (SIU) you have connected to make
sure it is the most current. (See Upgrade Main Firmware section under Maintenence in OSD Operation
for details.) If not, upgrade the SIUs firmware.
Press and release the left [Alt] key, then press and release the right [Alt] key.
When logging in from a browser, the
following message appears: 404
Object Not Found.
If a login string has been set (see Login String section under Device Management in OSD Operation
for details), make sure to include the forward slash and correct login string when you specify the B064-
Series KVM Switch IP address.
When I log in, the browser generates a
CA Root certificate is not trusted, or a
Certificate Error response.
The certificate can be trusted; you can proceed.
There are two mouse pointers after the
remote system is accessed.
The KVM automatically defaults to show both the local and remote mouse pointers. You can choose to
display both mouse pointers at the same time or only the remote mouse pointer. (See Mouse Pointer
section under OSD Main Page in OSD Operation for details.)
The display on the remote console is
distorted and performing an Autosync
doesn’t resolve the problem.
• Switch ports to a port with a different resolution and then switch back.
• Lower the resolution and refresh rate for the computer/server connected to the port.
I have been given an account, but I am
unable to login
Make sure that you have correctly entered your username and password
• Make sure that your System Administrator has given you proper access to the KVM switch
The Lock LEDs on the Control Panel do
not accurately portray my Lock status
Click the LEDs on the Control Panel until they match those on your keyboard. Once matched up,
changing a Lock LED on the keyboard will also change it in the Control Panel and vice versa.
When I open a viewer, the web page
does not display properly, and I receive
an error message that says “Problems
with this Web page might prevent it from
being displayed properly….
By default, IE6 and some versions of IE5 use the High security level for the Restricted Sites zone.
Windows Server 2003 uses High security for both the Restricted Sites and Internet zones. You may
need to enable Active Scripting, ActiveX Controls and Java Applets. To do this, follow these steps: 1)
In Internet Explorer, open the Tools menu and select Internet Options. 2) In the Internet Options dialog
box, click Security. 3) Click Default level, and click OK when prompted
Verify that Active Scripting, ActiveX Controls and Java Applets are not blocked. If some client computers
work and others don’t, verify the Internet Explorer or another program (e.g. Anti-Virus, Firewall, etc.) on
your client computer are not configured to block Scripts, ActiveX Controls or Java Applets.
Verify that your anti-virus program is not set to scan the Temporary Internet Files or Downloaded
Program Files folders
Delete all temporary internet related les by following these steps: 1) Open the Tools menu in Internet
Explorer and select Internet Options 2) Click on the General tab 3) Under Temporary Internet Files,
click Settings 4) Click Delete Files and click OK when prompted 5) Click Delete Cookies and click OK
when prompted 6) Under History, click on Clear History, Yes and click OK when prompted
Make sure that you have the latest version of Microsoft DirectX installed
Make sure that you have the latest version of Java installed
Problem Action
After upgrading the firmware and
logging back in, the B064-Series KVM
Switch appears to still be using the old
firmware version.
Clear your browser’s cache. Delete all temporary internet files and cookies. Close the browser and
reopen it to log in with a new session.