Use the M3x8 Phillips head hex screws
provided with the rack mount kit
Use user supplied
hardware to attach
to the rack
8
Hardware Setup (continued)
Rack Mounting Safety Instructions
• Beforeworkingontherack,makesurethatthestabilizersaresecuredtotherack,extendedtotheoor,andthatthefullweightoftherack
restsontheoor.Installfrontandsidestabilizersonasinglerackorfrontstabilizersforjoinedmultipleracks before working on the rack.
• Alwaysloadtherackfromthebottomup,andloadtheheaviestitemintherackrst.
• Makesurethattherackislevelandstablebeforeextendingadevicefromtherack.
• Usecautionwhenpressingthedevicerailreleaselatchesandslidingadeviceintooroutofarack;thesliderailscanpinchyourngers.
• Afteradeviceisinsertedintotherack,carefullyextendtherailintoalockingposition,andthenslidethedeviceintotherack.
• DonotoverloadtheACsupplybranchcircuitthatprovidespowertotherack.Thetotalrackloadshouldnotexceed80percentofthebranch
circuit rating.
• Makesurethatallequipmentusedontherack,includingpowerstripsandotherelectricalconnectors,isproperlygrounded.
• Ensurethatproperairowisprovidedfordevicesintherack.
• Ensurethattheoperatingambienttemperatureoftherackenvironmentdoesnotexceedthemaximumambienttemperaturespeciedforthe
equipment by the manufacturer.
• Donotsteponorstandonanydevicewhenservicingotherdevicesinarack.
The KVM switch can be placed on any level surface that can safely support its weight plus the weight of attached cables. When placing the KVM
switch on a desktop, remove the backing material from the rubber feet that came with this package and affix them to the switchs bottom panel at
the corners.
Note: To ensure adequate ventilation, allow at least 5 cm on each side, and 13 cm at the back for power cord and cable clearance.
The KVM switch can be mounted in a 19-in (1U) rack. The rack mount brackets can be installed on either the front or the back of the unit so that
it can be mounted to the front or back of the rack.
1. Depending on whether you front-rack mount or rear-rack mount the unit, remove the two screws located on both sides of the front or back of
the unit.
2. Use the screws supplied with the rack mount kit to attach the rack mount brackets to the front or rear of the unit.
3. Position the device in the front or rear of the rack and align the holes in the mount brackets with the holes in the rack.
4. Secure the rack mount brackets to the rack using user-supplied screws.
In a single-stage installation, there are no additional KVM switches cascaded or daisy-chained from the B064-Series KVM. To set up a single-
stage installation, refer to the following instructions and the corresponding installation diagrams.
1. Make sure that power to all the devices you will be connecting, including all pre-existing devices on the installation, have been turned off.
2. Optional: Plug your Local Consoles keyboard, monitor, and mouse into the KVM’s Local Console Ports. You will need to connect the
included USB – PS/2 Console Cable Kit to the console port on the back of the unit.
Note: You can use any combination of keyboard and mouse connections. For example, you can use a PS/2 keyboard with a USB mouse. USB
keyboards and mice can plug into the USB ports on the front panel, as well as the ports on the USB – PS/2 Console Cable Kit. The B064-Series
KVM Switch does not support distances above 65 ft between the KVM and the local monitor.
3. Use Cat5e cable to connect any available KVM port to a Server Interface Unit (SIU). See the chart in the Server Interface Unit section to
determine the appropriate SIU.
4. Connect the Server Interface Unit to the computer/server.
5. Connect a Cat5e cable from the network into the KVM switchs primary network port (LAN 1).
6. Optional: Connect a second Cat5e cable from the network into the KVM switchs backup (secondary) network port (LAN 2).
Stacking
Rack Mounting
Single-Stage Installation