Note
The
Console Server
s have an
snmptrap
daemon to send t
raps/notifications to remote SN
M
P
servers on defined trigger event
s
,
as detailed above.
The
Console Server
s also embed the
net
-
snmpd
daemon which accept SNMP requests from remote SNMP management serve
rs and
provides information on
network interface, running processes, disk usage
,
etc
.
(refer
to
Chapter
15.5 Modifying SNM
P Configuration
for more details)
.
7.1.
4
Nagios A
lerts
T
o
notify
the central
Nagios server of Alerts,
NSCA must be enabled under
System: Nagios
and Nagios
must be enabled for each applicable host or port under
Serial & N
etwork:
Network Hosts
or
Serial
&
Network:
Serial Ports
(refer
to
C
h
a
pter 10)
.
7.2
A
ctivate Alert Events and Notifications
The Alert
facility
monitors the status of the
Console Server
and connected devices
.
W
hen an alert even
t
is triggered, a notification is
emailed to a nominated ema
il address
or SMS gateway, or the configured
SNMP or Nagios server is notified.
A wide selection of events can be usedas the trigger for an alert. These events include:
A
user establishing a remote
Telnet
connecting to a serial port or Host
.
R
eaching a n
ominated low
-
battery level on a particular UPS or current load levels on a PDU
power outlet
.
E
xceeding a specifie
d temperature or humidity level
on an environmental sensor
.
S
ensing
a
particular data pattern on a serial port (e.g. the data stream on a parti
cular serial
console may be monitored for nominated messages coming from the device such as "warning"
or "IO error" and send out an alarm when they occur)
.