# /bin/config
-
del=config.services.pingreply.enabled
The following command will synchronize the live system with the
new co
nfiguration:
# /bin/config
-
run=services
Note: “/bin/config” commands can be combined into one command for convenience.
1
4
.5
Serial Port Configuration
14.5.1
Serial Port Settings
S
etup serial port 5 to use the following properties:
Baud Rate
11
5200
Parity
None
Data Bits
8
Stop Bits
1
Flow Control
Software
You would need to issue the following commands from the command line to set the port
configuration
:
# /bin/config
-
set=config.ports.port5.speed=115200
# /bin/config
-
set=config.ports.po
rt5.parity=None
# /bin/config
-
set=config.ports.port5.charsize=8
# /bin/config
-
set=config.ports.port5.stop=1
# /bin/config
-
set=config.ports.port5.flow=Software
The following command will synchronize the live sy
stem with the new configuration:
# /bin/
config
-
run=serialconfig
Note that supported serial port baud
-
rates are
50’, ‘75’, ‘110’, ‘134’, ‘150’, ‘200’, ‘300’, ‘600’,
‘1200’, ‘1800’, ‘2400’, ‘4800’, ‘9600’
, '19200', '38400', '57600', '115200', and '230400'.
Supported parity values are 'None',
'Odd', 'Even', 'Mark' and 'Space'
.
Supported data
-
bits values are '8', '7', '6' and '5'.
Supported stop
-
bits values are '1', '1.5' and '2'.
Supported flow
-
control values are 'Hardware', 'Software' and 'None'.