118
Check
Log Status
an
d
specify the
Log Rate
(
i.e.
minutes between samples) i
f you wish the status
from this UPS to be logged
. These logs can be views from the
Status: UPS Status
screen
.
Check
Enable Nagios
to enable this UPS to be m
onitored using Nagios central management
.
Click
Apply
.
You can also customize the
upsmon
,
upsd
and
upsc
settings for this UPS hardware directly from the
command line
.
.
2
Configure UPS P
owering the
Console Server
A
Monitored UPS
is a UPS
that
is prov
iding the power to
the
Console Server
. The purpose of configuring
a Monitored UPS
is to provide
an opportunity to perform any "
last gasp
" actions before power is lost
during
a power failure
.
This is achieved by placing a script in /
etc/config/scripts/ups
-
s
hutdown
.
You
may
use the
/etc/scripts/ups
-
shutdown
as a template
.
This script is run when then UPS reaches critical
battery status.
If the
Console Server
is drawing power through a Managed UPS
that has already been
configured
, select
Local
, enter the Manag
ed
UPS Name
and check
Enabled
.
The
Console Server
continu
es to be the master of this UPS
.
If the UPS that powers the
Console Server
is not a Managed UP
S for that
Console Server
, the
n
the
Console Server
can
still
connect to a remote NUT server (
upsd
) to
monitor its status as a
Slave
.
In this case, select
Remote
, and enter the address, username and password to connect.